Retatrutide for research: how to verify a Janoshik COA
How to read and verify a Janoshik COA for retatrutide: HPLC and mass spectrometry, the GLP-1 blind test, six checks, warning signs and a real example.
AI-generated illustration
To compare suppliers of retatrutide for research, in Europe or elsewhere, the certificate of analysis is the easiest document to check for yourself, without taking the seller’s word for it. This guide explains how to read and verify a Janoshik COA: what the methods measure, what the “GLP-1 peptide blind test” is worth, which checks to run and which signs should raise concern. It ends with a real verification, carried out step by step on one of our batches, followed by the figures for our own retatrutide batch.
What is a certificate of analysis (COA) for?
A certificate of analysis (COA) links a specific batch to measurements made by a laboratory: the identity of the molecule, its purity and the quantity contained in the vial. Without this link between the document and the batch, a purity percentage says nothing that can be verified.
For a laboratory comparing suppliers, the COA answers three questions. Is the molecule received the one that was ordered? What share of impurities did the method used detect? How much did the analysed vial actually contain, compared with the figure on the label?
The COA also has limits. It describes the sample sent to the laboratory, on a given date, and nothing else. It does not apply to another batch, to another vial size or to the state of the product months later. For the details of the techniques, our article HPLC and LC-MS do not answer the same question goes further.
HPLC and mass spectrometry: what each one proves and does not prove
Chromatographic purity, measured mass and quantity in milligrams answer three different questions: none of these figures replaces the other two. Reading a COA starts with knowing which question each figure answers.
HPLC: a relative purity
Liquid chromatography (HPLC) separates the components of the sample, which appear as peaks. The stated purity is the share of the main peak among all the peaks detected, under the conditions of the method. It shows that the sample contains few impurities visible with this method. On its own, this percentage does not show that the main peak is the right molecule: another peptide, well purified, would also show a high percentage.
Mass spectrometry: identity
Mass spectrometry measures the mass-to-charge ratio of the ions formed from the sample, from which the mass of the molecules present is deduced. A mass that matches the expected one supports the identification of the compound, which the purity percentage does not do. The ICH Q2(R2) guideline on the validation of analytical procedures uses the terms specificity and selectivity to describe how far other substances interfere with the determination of the one being sought. That is exactly the issue when several closely related peptides exist.
What neither of them proves
Neither purity nor identity says anything about the content of trifluoroacetic acid (TFA), heavy metals or endotoxins. At Janoshik, these are separate analyses, offered as options, which only appear on a report if they were ordered. A COA that is silent on these points says nothing about them, good or bad.
Janoshik’s GLP-1 blind test for retatrutide
For retatrutide, identity matters as much as purity, and that is precisely what Janoshik’s blind test is designed for. A Janoshik retatrutide report is therefore read first by its title.
Retatrutide (LY3437943) is an agonist of three receptors, those for GIP, GLP-1 and glucagon, as described in a structural study published in 2024; our comparison with tirzepatide covers these receptors in detail. On a chromatogram, however, a pure sample of semaglutide or tirzepatide can show a purity as high as pure retatrutide. A labelling error or a substitution would therefore go unnoticed if the report gave only the purity.
Janoshik’s test is called “Common GLP-1 peptide blind test (Semaglutide, Tirzepatide and Retatrutide)”. According to its page published by the laboratory, the client does not have to say which of the three peptides it expects. The test identifies the one that is present, then measures its quantity and purity; in a mixture, each one is identified and quantified. The stated method is HPLC, the result is given in milligrams per vial, and the laboratory asks for at least one whole, unopened vial.
On such a report, three items deserve attention:
- the title of the test, which names the three peptides looked for;
- the molecule identified and the quantity measured, in milligrams;
- the laboratory’s comments: the report for our batch RET15-001 states “Sample was tested twice”, meaning the sample was analysed twice.
Checklist: 6 points to verify a Janoshik COA
A Janoshik COA can be verified with six simple checks; a single point that does not match is enough to ask the seller for an explanation.
- The batch of your order is the one on the report. When the vial bears a batch number, compare it with the “Batch” field of the report; otherwise, ask the seller for the batch of your order. Then find this batch in the report, or on the seller’s page that links it to a verification key. A report tied to no batch is tied to no vial.
- The key can be checked on the laboratory’s website. Each report carries a verification key, twelve characters long on our reports (for example JW6VRH2XBBNI), and invites readers to check it at
www.janoshik.com/verify/. The public link to a report, hosted onverify.janoshik.com, ends with the same key. Consult the report on the laboratory’s website, not as an image received from someone. - The dates are recent and consistent with the batch. The report states when the analysis was ordered, when the sample was received and when the analysis was carried out. An analysis that predates the manufacture of a batch cannot describe it: ask for the batch date if it appears nowhere.
- The measured quantity is compared with the label, with the difference quantified. Compare the milligrams measured with those on the label and calculate the difference as a percentage. The measurement describes the vial analysed: it says more than the label about the batch, without saying how much the vials of one batch vary from each other.
- The size analysed is that of the vial in hand. The report for a 15 mg vial does not measure the contents of a 5 mg or 30 mg vial of the same product. If one report accompanies several sizes, it must say which one was analysed: check that it is the size of your vial.
- The laboratory is independent of the seller. The report must come from an identifiable third-party laboratory that publishes its results itself. Keep one limit in mind: the seller chooses the sample that is sent, hence the value of being able to tie each report to a specific batch.
Warning signs on a peptide certificate of analysis
Some certificates prove nothing, even with a high purity figure in large print. These signs should raise doubts:
- no batch number: the document is tied to no vial;
- an image alone: a screenshot or PDF with no key and no link to the laboratory’s website, even though an image is easy to alter;
- an analysed size left unstated: a report presented for sizes other than the one analysed, without saying so;
- an old date: a report several years old for a product sold today, with no matching batch;
- an unknown laboratory: a name that cannot be found, no website, no public verification of reports;
- a different manufacturer name: the report carries a name other than the seller’s. There may be an explanation, such as a former name or a former domain, but it has to be given.
Real example, step by step: BPC-157 batch BPC10-001
Here is the complete verification of our BPC-157 batch BPC10-001, as anyone can repeat it. This batch shows the simplest case, with a report issued under the current name of Optima Labs; retatrutide follows right after.
Step 1: get the batch of your order
At Optima Labs, the batch number is printed neither on the vial nor on the packaging: you ask support for it, with your order number. Here, support gives batch BPC10-001. This is the identifier to look for at each of the following steps.
Step 2: find the certificate for the batch
The BPC10-001 batch page shows the certificate, the laboratory and the key JW6VRH2XBBNI. This page is what links the batch of the order to the laboratory report. All our analyses are gathered on the Laboratory testing page.
Step 3: open the report at Janoshik
Public report No. 198957 opens on Janoshik’s website. Its address contains the task number, the sample name and the key JW6VRH2XBBNI, which is also printed at the bottom of the report.
Step 4: compare the report with the batch page
| Item checked | Order and batch page | Janoshik report No. 198957 |
|---|---|---|
| Batch | BPC10-001 | BPC10-001 |
| Sample | BPC-157 10 mg | BPC-157 10 mg |
| Manufacturer | Optima Labs | Optima Labs |
| Client | – | Optima Labs LLC |
| Verification key | JW6VRH2XBBNI | JW6VRH2XBBNI |
| Test requested | – | BPC-157 analysis |
| Dates | analysis ordered on 23 June 2026, sample received on 25 June | analysis ordered on 23 June 2026, sample received on 25 June, analysis carried out on 1 July |
| Quantity | 10.29 mg measured for 10 mg stated (+2.9%) | 10.29 mg measured |
| Purity | 99.74% | 99.740% |
Step 5: read the difference and conclude
The laboratory measured 10.29 mg for 10 mg stated, which is 2.9% more than the label, with a purity of 99.740%. Batch, key, vial size and manufacturer match: this report documents the sample of batch BPC10-001 sent to the laboratory, and no other batch.
Transparency: our retatrutide batch RET15-001
Our retatrutide batch RET15-001 was analysed by Janoshik with the GLP-1 blind test: 99.910% purity and 19.67 mg measured for 15 mg stated. That is 31% more than the stated quantity: the actual content differs markedly from the label. This is the difference the fourth point of the checklist asks you to quantify.
Public report No. 165808 carries the key 334EJNY1WHYW, which can also be found on the RET15-001 batch page. The analysis was ordered on 19 May 2026, the sample was received on 22 May and the analysis was carried out on 27 May 2026; the laboratory notes that the sample was tested twice.
One point stands out: the manufacturer written on this report is optima-labs.net, the former domain of Optima Labs; the client field of the same report reads Optima Labs. Our two Janoshik reports from May 2026 carry this manufacturer name, and our four reports from June 2026 carry the name Optima Labs. This is the case described above among the warning signs: a different name calls for an explanation, and here it is.
This report covers a 15 mg vial: the certificate says so by naming the sample analysed, “Retatrutide 15 mg”. Under the fifth point of the checklist, it does not measure the contents of the other sizes offered on the retatrutide product page, even if it is displayed next to them there: under each of them, the product page names the sample analysed, and the batch page states that the analysis covers the 15 mg. All the analyses of this molecule, with their batch and key, are grouped on the retatrutide analyses page.
Finally, to place the supplier: Optima Labs LLC, the company listed as client on our June reports, has its head office in New Mexico, in the United States, and ships from a logistics centre located in the European Union. The Why trust us page brings this information together.
These products are intended exclusively for scientific research and are not for human consumption.
Catalogue pages related to the molecules discussed: BPC-157 · GHK-Cu · GHK-Cu pen · Retatrutide pen · Tirzepatide. See their product pages for dosages, specifications and available analyses. Publications about the molecules do not validate these commercial products.
Frequently asked questions
What is a Janoshik COA?
It is an analysis report issued by Janoshik, a third-party laboratory, for a sample sent by its client. It states the batch, the sample, the test requested, the dates, the results (most often the measured quantity and the purity) and a key that allows the report to be found on the laboratory’s website.
How can one tell whether a retatrutide COA matches the vial received?
Find the batch of your order in the “Batch” field of the report: on the vial when it appears there, otherwise from the seller (at Optima Labs, support gives it with your order number). Then open the report on Janoshik’s website with its key, and check that the size tested is that of the vial. If any of these points differs, the report does not document this vial.
Why a blind test for retatrutide?
Because a high purity does not say which molecule is present. Janoshik’s GLP-1 blind test covers semaglutide, tirzepatide and retatrutide: the client does not state which one it expects, the laboratory identifies the one that is present, then measures its quantity and purity.
Is a measured quantity above the label a defect?
It is a difference like any other: above or below the label, it is quantified and reported, because it shows that the actual content moves away from the label. For our batch RET15-001, Janoshik measured 19.67 mg for 15 mg stated, which is 31% more.
Why does the report for batch RET15-001 mention optima-labs.net?
It is the former domain of Optima Labs. Our two Janoshik reports from May 2026, retatrutide and GHK-Cu, carry this manufacturer name; our four reports from June 2026 carry the name Optima Labs.
Are these compounds intended for human use?
No. Optima Labs compounds are intended exclusively for in vitro research and laboratory testing, not for human, animal or food use.
Published batch certificates of analysis are gathered on the Laboratory testing page.
Informational and educational content. Optima Labs supplies compounds intended exclusively for laboratory research and in vitro testing | not for human, animal or food use. Research disclaimer (in French).
Optima Labs